Skip to Header Skip to Main Content Skip to Footer
Here at Distrelec we sell a selection of insulation testers from highly regarded manufacturers such as Beha-Amprobe, Benning, Chauvin Anoux, Extech Instruments, Fluke, Gossen Metrawatt, and many more. The manufacturers that we partner with are well known suppliers that we know you can trust.
Manufacturer
Product Status
Interface Type
Protection Rating Min IK04 IP40 IP43 IP52 IP53 IP54 IP65 Max IK04 IP40 IP43 IP52 IP53 IP54 IP65
Measuring Functions Min 3P Earth AC/DC Milliamps AC/DC Millivolts AC/DC Voltage AC/DC Withstanding Voltage AC Current AC Voltage Additional High Current Loop Mode Auto-Discharge Automatic Calculation of Dielectric Absorption (DAR) Automatic Discharge Function Automatic Discharge of Circuit Capacitance Automatic RCD Test Sequence Automatic Test Start for Loop & RCD Tests Auto Resistivity Calculation Auto Test to Test Line/Loop Impedance Capacitance Continuity Continuity & Resistance Measure Motor Windings Continuity at L-N, N-PE Inputs Continuity Resistance Current Current (Optional) Current (with Clamp) DC Current DC Sensitive RCD Testing DC Voltage Dielectric Absorption Rate (DAR) Dielectric Absorption Ratio Dielectric Absorption Ratio (DAR) Dielectric Discharge (DD) Differential Fault Currents Diode Test Earth / Ground Test Earth Bond Resistance Earth-Bond Resistance Earth Ground Resistance Earthing Resistance Earth Leakage Earth Leakage Resistance Earth Loop Earth Resistance Earth Resistance, Voltage & Frequency Fast Voltage Measurement between L-N, L-PE & N-PE Fault Loop Frequency Ground Bond Harmonics IMD/RCM Testing Impedance Insulation Insulation Resistance Insulation Resistance, Continuity & Resistance Insulation Testing Insulation Tests Internal Net Resistance Leakage Current Leakage Current (with Clamp) Lock/Timing s Loop Loop & Line Impedance Loop & Line Resistance Loop Impedance Loop Impotence Loop Resistance Low-Impedance & Continuity Testing Low Ohm Resistance Low Resistance Low Resistance and Continuity Mains Internal Resistance Measure Motor Windings with Continuity Test, Loop & Line Resistance Measure RCD Trip Current & Trip Time in Parallel (RCD Type AC & A) Measures Trip Time & Current Memory Motor Winding Testing Non-Trip Loop Test Null Balance of the Measuring Leads Phase Sequence Phase Sequence Indicator Polarisation Index Polarisation Index (PI) Polarization Index/Dielectric Absorption Ratio s Polarization Index (PI) Power Power Consumption of Devices without Breaking the Circuit Prospective Earth Fault Current Prospective Earth Fault Current (PEFC/IK) Prospective Short-Circuit Current Prospective Short-Circuit Current (PSC/IK) Protective Conductor Resistance Ramp Function Ramp Test RCD RCD/FI RCD / FI RCD Switching Time RCD Test RCD Tests RCD Trip Current/Trip Time RCD Tripping Level RCD Tripping Level, Measures Trip Time & Current RCD Tripping Level (Ramp Test) RCD Variable Current Residual Voltage Resistance Resistance and Continuity Ring Testing RMS Measurements Selective Earthing Resistance Short Circuit Current Short-Circuit Current Soil Resistance Soil Resistivity (with Adapter) Step Increments Stepped Voltage (SV) & Ramp Test Supply Measurement SV Temperature Test Smooth DC Sensitive RCDs (Type B) Test Voltage Timer for Time Function Tolerance Tripping Current Tripping Time True RMS Voltage Voltage & Frequency Voltage Drop Wiring Polarity Check Wiring Polarity Checker Withstanding Voltage Z-Line Z-Loop Z-max Memory for Loop Tests Max 3P Earth AC/DC Milliamps AC/DC Millivolts AC/DC Voltage AC/DC Withstanding Voltage AC Current AC Voltage Additional High Current Loop Mode Auto-Discharge Automatic Calculation of Dielectric Absorption (DAR) Automatic Discharge Function Automatic Discharge of Circuit Capacitance Automatic RCD Test Sequence Automatic Test Start for Loop & RCD Tests Auto Resistivity Calculation Auto Test to Test Line/Loop Impedance Capacitance Continuity Continuity & Resistance Measure Motor Windings Continuity at L-N, N-PE Inputs Continuity Resistance Current Current (Optional) Current (with Clamp) DC Current DC Sensitive RCD Testing DC Voltage Dielectric Absorption Rate (DAR) Dielectric Absorption Ratio Dielectric Absorption Ratio (DAR) Dielectric Discharge (DD) Differential Fault Currents Diode Test Earth / Ground Test Earth Bond Resistance Earth-Bond Resistance Earth Ground Resistance Earthing Resistance Earth Leakage Earth Leakage Resistance Earth Loop Earth Resistance Earth Resistance, Voltage & Frequency Fast Voltage Measurement between L-N, L-PE & N-PE Fault Loop Frequency Ground Bond Harmonics IMD/RCM Testing Impedance Insulation Insulation Resistance Insulation Resistance, Continuity & Resistance Insulation Testing Insulation Tests Internal Net Resistance Leakage Current Leakage Current (with Clamp) Lock/Timing s Loop Loop & Line Impedance Loop & Line Resistance Loop Impedance Loop Impotence Loop Resistance Low-Impedance & Continuity Testing Low Ohm Resistance Low Resistance Low Resistance and Continuity Mains Internal Resistance Measure Motor Windings with Continuity Test, Loop & Line Resistance Measure RCD Trip Current & Trip Time in Parallel (RCD Type AC & A) Measures Trip Time & Current Memory Motor Winding Testing Non-Trip Loop Test Null Balance of the Measuring Leads Phase Sequence Phase Sequence Indicator Polarisation Index Polarisation Index (PI) Polarization Index/Dielectric Absorption Ratio s Polarization Index (PI) Power Power Consumption of Devices without Breaking the Circuit Prospective Earth Fault Current Prospective Earth Fault Current (PEFC/IK) Prospective Short-Circuit Current Prospective Short-Circuit Current (PSC/IK) Protective Conductor Resistance Ramp Function Ramp Test RCD RCD/FI RCD / FI RCD Switching Time RCD Test RCD Tests RCD Trip Current/Trip Time RCD Tripping Level RCD Tripping Level, Measures Trip Time & Current RCD Tripping Level (Ramp Test) RCD Variable Current Residual Voltage Resistance Resistance and Continuity Ring Testing RMS Measurements Selective Earthing Resistance Short Circuit Current Short-Circuit Current Soil Resistance Soil Resistivity (with Adapter) Step Increments Stepped Voltage (SV) & Ramp Test Supply Measurement SV Temperature Test Smooth DC Sensitive RCDs (Type B) Test Voltage Timer for Time Function Tolerance Tripping Current Tripping Time True RMS Voltage Voltage & Frequency Voltage Drop Wiring Polarity Check Wiring Polarity Checker Withstanding Voltage Z-Line Z-Loop Z-max Memory for Loop Tests
Test Voltage Min 4 V 50 V 100 V 125 V 250 V 500 V 600 V 1 kV 2.5 kV 3.7 kV 5 kV 5.55 kV 8.5 kV 10 kV 15 kV Max 4 V 50 V 100 V 125 V 250 V 500 V 600 V 1 kV 2.5 kV 3.7 kV 5 kV 5.55 kV 8.5 kV 10 kV 15 kV
Display Type
Other Measuring Ranges Min 1 nF ... 10 uF 400 ... 700 V 400 mA AC / DC Current AC / DC Voltage: 0 ... 1 kV AC / DC Voltage: 0 ... 600 V AC / DC Voltage: 1 kV AC Voltage: 0 ... 600 V AC Voltage: 50 V ... 5 kV AC Voltage: 600 mV ... 1000 V AC Voltage: 750 V AC Voltage Measurement: 500 V AC Withstanding Output Voltage: 0.05 kV ... 5 kV AC Withstanding Output Voltage: 0.1 kV ... 5 kV Capacitance Capacitance: ±5 nF Capacitance: 0.01uF ... 15.00uF Capacitance: 0.1 nF ... 10 uF Capacitance: 10 mF Capacitance: 10 nF ... 2 uF Capacitance: 30 nF ... 300 uF Continuity: 0.01 ... 100 Ohm Continuity: 0.01 ... 99.9 Ohm Continuity: 0.01 Ohm ... 1 MOhm Continuity: 0.01 Ohm ... 999 kOhm Continuity: 100 mOhm ... 90 Ohm Continuity: 100 Ohm Continuity: 400 Ohm Continuity: 40 Ohm Continuity: 600 Ohm Continuity Testing (RLO): 20 ... 2000 Ohm DC Voltage: 0 ... 600 V DC Voltage: 1000 V DC Voltage: 50 V ... 6 kV DC Voltage: 6 V ... 1000 V DC Withstanding Output Voltage: 0.05 kV ... 6 kV DC Withstanding Output Voltage: 0.1 kV ... 6 kV Diode Test: 2 V Earth Bond Resistance: 1 mOhm ... 650 mOhm Earth Bond Resistance Measurement: 20 Ohm ... 20 kOhm Frequency: 15 ... 400 Hz Frequency: 15 ... 99 Hz Frequency: 16 ... 400 Hz Frequency: 300 Hz ... 300 kHz Frequency: 45 ... 65 Hz Impedance: 0 ... 2 kOhm Leakage Current: 1 nA ... 2 mA Leakage Current: 1 nA ... 3 mA Loop & Line Impedance: 10 Ohm / 0.001 Ohm / High Current MOhm Mode Low Resistance: 0.01 Ohm ... 100 Ohm Low Resistance: 0.01 Ohm ... 20 kOhm Low Resistance: 0.1 Ohm ... 999.9 Ohm Prospective Earth Fault Current, PSC Test: 1000 A / 10 kA (50 kA) RCD Trip Current Measurement / Ramp Test: Type G: 300 ms/Step RCD Type S: 510 / 160 ms Resistance: 0 ... 200 Ohm Resistance: 0 ... 60 kOhm Resistance: 0.01 Ohm ... 40 kOhm Resistance: 420 kOhm Resistance: 50 MOhm Resistance: 600 kOhm Resistance: 600 Ohm Resistance: 60 kOhm Resistance: 6 kOhm Surge Voltage: 40 ... 1050 V Temperature: -10 ... 50 °C Temperature: -250 ... 1372 °C Tripping Speed Test: RCD Type G: 310 / 50 ms Type S: 500 ms / Step Voltage: 0 ... 2000 VAC / DC Voltage: 0 ... 600 V Voltage: 0.1V ... 600 VAC / DC Voltage: 0.3 ... 399.9 V Voltage: 10 ... 600 V Voltage: 120 ... 400 V Voltage: 30 ... 600 V Voltage: 300 mV ... 1 kV Voltage: 700 V Max 1 nF ... 10 uF 400 ... 700 V 400 mA AC / DC Current AC / DC Voltage: 0 ... 1 kV AC / DC Voltage: 0 ... 600 V AC / DC Voltage: 1 kV AC Voltage: 0 ... 600 V AC Voltage: 50 V ... 5 kV AC Voltage: 600 mV ... 1000 V AC Voltage: 750 V AC Voltage Measurement: 500 V AC Withstanding Output Voltage: 0.05 kV ... 5 kV AC Withstanding Output Voltage: 0.1 kV ... 5 kV Capacitance Capacitance: ±5 nF Capacitance: 0.01uF ... 15.00uF Capacitance: 0.1 nF ... 10 uF Capacitance: 10 mF Capacitance: 10 nF ... 2 uF Capacitance: 30 nF ... 300 uF Continuity: 0.01 ... 100 Ohm Continuity: 0.01 ... 99.9 Ohm Continuity: 0.01 Ohm ... 1 MOhm Continuity: 0.01 Ohm ... 999 kOhm Continuity: 100 mOhm ... 90 Ohm Continuity: 100 Ohm Continuity: 400 Ohm Continuity: 40 Ohm Continuity: 600 Ohm Continuity Testing (RLO): 20 ... 2000 Ohm DC Voltage: 0 ... 600 V DC Voltage: 1000 V DC Voltage: 50 V ... 6 kV DC Voltage: 6 V ... 1000 V DC Withstanding Output Voltage: 0.05 kV ... 6 kV DC Withstanding Output Voltage: 0.1 kV ... 6 kV Diode Test: 2 V Earth Bond Resistance: 1 mOhm ... 650 mOhm Earth Bond Resistance Measurement: 20 Ohm ... 20 kOhm Frequency: 15 ... 400 Hz Frequency: 15 ... 99 Hz Frequency: 16 ... 400 Hz Frequency: 300 Hz ... 300 kHz Frequency: 45 ... 65 Hz Impedance: 0 ... 2 kOhm Leakage Current: 1 nA ... 2 mA Leakage Current: 1 nA ... 3 mA Loop & Line Impedance: 10 Ohm / 0.001 Ohm / High Current MOhm Mode Low Resistance: 0.01 Ohm ... 100 Ohm Low Resistance: 0.01 Ohm ... 20 kOhm Low Resistance: 0.1 Ohm ... 999.9 Ohm Prospective Earth Fault Current, PSC Test: 1000 A / 10 kA (50 kA) RCD Trip Current Measurement / Ramp Test: Type G: 300 ms/Step RCD Type S: 510 / 160 ms Resistance: 0 ... 200 Ohm Resistance: 0 ... 60 kOhm Resistance: 0.01 Ohm ... 40 kOhm Resistance: 420 kOhm Resistance: 50 MOhm Resistance: 600 kOhm Resistance: 600 Ohm Resistance: 60 kOhm Resistance: 6 kOhm Surge Voltage: 40 ... 1050 V Temperature: -10 ... 50 °C Temperature: -250 ... 1372 °C Tripping Speed Test: RCD Type G: 310 / 50 ms Type S: 500 ms / Step Voltage: 0 ... 2000 VAC / DC Voltage: 0 ... 600 V Voltage: 0.1V ... 600 VAC / DC Voltage: 0.3 ... 399.9 V Voltage: 10 ... 600 V Voltage: 120 ... 400 V Voltage: 30 ... 600 V Voltage: 300 mV ... 1 kV Voltage: 700 V
Insulation Resistance Accuracy Min ±1.5 % ±1 % ±10 % ±2 % ±20 % ±25 % ±3 % ±30 % ±5 ... ±20 % ±5 % ±6 % 0 ... 20 % Max ±1.5 % ±1 % ±10 % ±2 % ±20 % ±25 % ±3 % ±30 % ±5 ... ±20 % ±5 % ±6 % 0 ... 20 %
Insulation Resistance Max. Min 200 Ohm 2 kOhm 99.9 kOhm 1 MOhm 300 MOhm 400 MOhm 499 MOhm 500 MOhm 600 MOhm 999 MOhm 999.9 MOhm 1 GOhm 2 GOhm 3.1 GOhm 4 GOhm 5.5 GOhm 9.5 GOhm 10 GOhm 11 GOhm 20 GOhm 40 GOhm 50 GOhm 99.9 GOhm 100 GOhm 200 GOhm 500 GOhm 999 GOhm 1 TOhm 2 TOhm 5 TOhm 10 TOhm 20 TOhm 30 TOhm Max 200 Ohm 2 kOhm 99.9 kOhm 1 MOhm 300 MOhm 400 MOhm 499 MOhm 500 MOhm 600 MOhm 999 MOhm 999.9 MOhm 1 GOhm 2 GOhm 3.1 GOhm 4 GOhm 5.5 GOhm 9.5 GOhm 10 GOhm 11 GOhm 20 GOhm 40 GOhm 50 GOhm 99.9 GOhm 100 GOhm 200 GOhm 500 GOhm 999 GOhm 1 TOhm 2 TOhm 5 TOhm 10 TOhm 20 TOhm 30 TOhm
Insulation Resistance Min. Min 0 GOhm 1 mOhm 10 mOhm 10 Ohm 50 Ohm 200 Ohm 300 Ohm 1 kOhm 10 kOhm 50 kOhm 99.9 kOhm 100 kOhm 125 kOhm 200 kOhm 300 kOhm 1 MOhm 4 MOhm 20 MOhm 50 MOhm 100 MOhm 200 MOhm 600 MOhm 2 GOhm 4 GOhm 9.5 GOhm 10 GOhm 20 GOhm 50 GOhm 100 GOhm 200 GOhm Max 0 GOhm 1 mOhm 10 mOhm 10 Ohm 50 Ohm 200 Ohm 300 Ohm 1 kOhm 10 kOhm 50 kOhm 99.9 kOhm 100 kOhm 125 kOhm 200 kOhm 300 kOhm 1 MOhm 4 MOhm 20 MOhm 50 MOhm 100 MOhm 200 MOhm 600 MOhm 2 GOhm 4 GOhm 9.5 GOhm 10 GOhm 20 GOhm 50 GOhm 100 GOhm 200 GOhm
Insulation Resistance Resolution Min 0 ... 1 TOhm 0.01 MOhm ... 1 MOhm 0.01 Ohm 0.1 kOhm 0.1 mOhm 100 kOhm 10 kOhm 10 kOhm / 100 kOhm 10 kOhm ... 1 MOhm 10 M 1 Hz 1 kOhm 1 MOhm 1 MOhm ... 1 GOhm Max 0 ... 1 TOhm 0.01 MOhm ... 1 MOhm 0.01 Ohm 0.1 kOhm 0.1 mOhm 100 kOhm 10 kOhm 10 kOhm / 100 kOhm 10 kOhm ... 1 MOhm 10 M 1 Hz 1 kOhm 1 MOhm 1 MOhm ... 1 GOhm
Safety Category
Short Circuit Current Min 1 mA 1.3 mA 1.5 mA 1.8 mA 2 mA 3 mA 5 mA 10 mA 12 mA 100 mA 200 mA 205 mA Max 1 mA 1.3 mA 1.5 mA 1.8 mA 2 mA 3 mA 5 mA 10 mA 12 mA 100 mA 200 mA 205 mA
Test Current Min 1 mA 1.5 mA 2 mA 3 mA 12 mA 200 mA 1 A 10 A 25 A Max 1 mA 1.5 mA 2 mA 3 mA 12 mA 200 mA 1 A 10 A 25 A
Tester Type